Model NO.: BT-600CA/253Yx
HS Code: 8413609090
Model NO.: BT-600CA/253Yx
HS Code: 8413609090
Flow Rate (ml/min,medium:water)
Pump head | 153Yx | 253Yx | ||||||||
Tube | 14# | 16# | 25# | 17# | 18# | 15# | 24# | Â 35# | 36# | |
ID×wall | 1.6×1.6 | 3.2×1.6 | 4.8×1.6 | 6.4×1.6 | 7.9×1.6 | 4.8×2.4 | 6.4×2.4 | 7.9×2.4 | 9.7×2.4 | |
Flow rate | 0.03~125 | 0.08~470 | 0.17~1120 | 0.3~1780 | 0.4~2200 | 0.2~900 | 0.3~1620 | 0.4~2340 | 0.5~3000 | |
Note | 1.Above date is measured in our laboratory at room temperature , for reference only; 2.Tubing material, size, Viscosity, suction and lifting length will have some impact on flow rate. |
Pump head | DGX | 314D | ||||||
Tube | 14# | 16# | 25# | 14# | 16# | 25# | 17# | 18# |
ID×wall | 1.6×1.6 | 3.1×1.6 | 4.8×1.6 | 1.6×1.6 | 3.2×1.6 | 4.8×1.6 | 6.4×1.6 | 7.9×1.6 |
Flow rate | 0-150 | 0-450 | 0-593 | 0.03-162 | 0.08-630 | 0.17-1056 | 0.3-1848 | 0.4-2280 |
Note | 1.Above date is measured in our laboratory at room temperature , for reference only; 2.Tubing material, size, Viscosity, suction and lifting length will have some impact on flow rate. |
Feature
DG with multichannel, 153Yx and 253Yx pump head can be connected in series, 314D can not be connected in seriesPump head material, PPS, is strongly corrosion-resistance; Lightly color PSU can resist from chemical corrosion.
The function of pump is timing and storage, setting operation and stopping time and programming times, so as to dispense and delay shutdown conveniently.
Operation of membrane switch: starting/stopping,clockwise and counter-clockwise, up and down speed, timing and dispensing settings.
External signal controlling: foot switch, analog signal (0-5V 0-10V 4-20mA) and MODBUS general agreement.
Standard configuration: digital display driver, pump head, tubes (2 meters optional).Â
Optional configuration: footswitch, spare tubes, filling needle, tube connector, and anti-floating head.
Â
Specification
Display | Graphic LCD display |
Rotary sepeed | 0.1~600rpm,cw/ccw rotation |
speed adiustment | Rotary switch |
Function | Adjusting flow rate,timing,filling |
Basic functions | full-speed emptying, sucking-back angle setting, flow correcting, timing, working temperature detecting. |
Sucking-backangle | 0~360°optional |
Footswitch | Identify foot switch automatically(the pump can be set as jogging or continuing condition) |
Filling | The pump can be set to run automatically or infrared sensor running (no container, no filling) |
Size | Length 304×width166×high178(mm) ,weight:4.1-5.1Kg |
Working environment | 0-60ºC,relative humidity85% |
Power | Ac220V50/60Hz (Ac110V50/60Hzoptional),54W |
Pressure | ≤0.2Mpa(If working time is short, the outlet pressure can get 0.27Mpa) |
External control | Starting/stopping,CW/CCW,speed controlling:0.5-5V/10V,4-20mA,0-10KHz;RS485communication fits with MODBUS agreement. |
IP rating | IP31 |
BT-300CA/153Yx/253Yx Dimension

Â

Â
BT-300CA/DGX Dimension

Â

Â
Â
Flow Rate (ml/min,medium:water)
Pump head | 153Yx | 253Yx | ||||||||
Tube | 14# | 16# | 25# | 17# | 18# | 15# | 24# | Â 35# | 36# | |
ID×wall | 1.6×1.6 | 3.2×1.6 | 4.8×1.6 | 6.4×1.6 | 7.9×1.6 | 4.8×2.4 | 6.4×2.4 | 7.9×2.4 | 9.7×2.4 | |
Flow rate | 0.03~125 | 0.08~470 | 0.17~1120 | 0.3~1780 | 0.4~2200 | 0.2~900 | 0.3~1620 | 0.4~2340 | 0.5~3000 | |
Note | 1.Above date is measured in our laboratory at room temperature , for reference only; 2.Tubing material, size, Viscosity, suction and lifting length will have some impact on flow rate. |
Pump head | DGX | 314D | ||||||
Tube | 14# | 16# | 25# | 14# | 16# | 25# | 17# | 18# |
ID×wall | 1.6×1.6 | 3.1×1.6 | 4.8×1.6 | 1.6×1.6 | 3.2×1.6 | 4.8×1.6 | 6.4×1.6 | 7.9×1.6 |
Flow rate | 0-150 | 0-450 | 0-593 | 0.03-162 | 0.08-630 | 0.17-1056 | 0.3-1848 | 0.4-2280 |
Note | 1.Above date is measured in our laboratory at room temperature , for reference only; 2.Tubing material, size, Viscosity, suction and lifting length will have some impact on flow rate. |
Feature
DG with multichannel, 153Yx and 253Yx pump head can be connected in series, 314D can not be connected in seriesPump head material, PPS, is strongly corrosion-resistance; Lightly color PSU can resist from chemical corrosion.
The function of pump is timing and storage, setting operation and stopping time and programming times, so as to dispense and delay shutdown conveniently.
Operation of membrane switch: starting/stopping,clockwise and counter-clockwise, up and down speed, timing and dispensing settings.
External signal controlling: foot switch, analog signal (0-5V 0-10V 4-20mA) and MODBUS general agreement.
Standard configuration: digital display driver, pump head, tubes (2 meters optional).Â
Optional configuration: footswitch, spare tubes, filling needle, tube connector, and anti-floating head.
Â
Specification
Display | Graphic LCD display |
Rotary sepeed | 0.1~600rpm,cw/ccw rotation |
speed adiustment | Rotary switch |
Function | Adjusting flow rate,timing,filling |
Basic functions | full-speed emptying, sucking-back angle setting, flow correcting, timing, working temperature detecting. |
Sucking-backangle | 0~360°optional |
Footswitch | Identify foot switch automatically(the pump can be set as jogging or continuing condition) |
Filling | The pump can be set to run automatically or infrared sensor running (no container, no filling) |
Size | Length 304×width166×high178(mm) ,weight:4.1-5.1Kg |
Working environment | 0-60ºC,relative humidity85% |
Power | Ac220V50/60Hz (Ac110V50/60Hzoptional),54W |
Pressure | ≤0.2Mpa(If working time is short, the outlet pressure can get 0.27Mpa) |
External control | Starting/stopping,CW/CCW,speed controlling:0.5-5V/10V,4-20mA,0-10KHz;RS485communication fits with MODBUS agreement. |
IP rating | IP31 |
BT-300CA/153Yx/253Yx Dimension

Â

Â
BT-300CA/DGX Dimension

Â

Â
Â
Artificial Turf Machine & Tools
Artificial Turf Machine & Tools is used to construct and maintance artificial turf.
Artificial Turf Machine & Tools,Sand Brushing Machine,Artificial Grass Brushing Machine,Artificial Turf Sand Filling Machine
WUXI DEIICHEN MACHINERY PTY.,LTD , https://www.medicineprocessing.com