Five errors in electronic scales and their solutions

Electronic scales as the core components of electronic scales, its quality is directly related to the use of electronic scales. Certain display problems, the user should first understand some basic causes of failure and solutions, so as not to affect the use of electronic scales and normal production. Today Xiao Bian came to tell everyone about the electronic floor scale 5 display faults and solutions, I hope you can read this article carefully, I hope this article can bring you some help.

1. The figures displayed on the display are not stable when the electronic and electronic scales are weighed.

Solution: First check whether the electronic and electronic scales are placed on the horizontal plane and whether the four scales are leveled. Then adjust the position of the electronic and electronic scales and scales.

Second, when the electronic electronic scale is opened, the display shows numbers and there is no regular jumping.

Solution: This situation is often due to the water vapor in the electronic junction box is too heavy or water. It should quickly disassemble the junction box to detect whether the water and dry with a hair dryer.

Third, electronic and electronic weighing scales after the normal start of the weighing results are light or heavy.

Solution: At this time, it needs to be recalibrated according to the instruction manual. If the problem of electronic and electronic scales has not been solved after calibration, it can basically be confirmed as the cause of damage to electronic scale sensors.

4. After the electronic scales are weighed, the display will not return to zero after the weighing object is removed.

Solution: The above situation should be that the line is damaged and the signal is attenuated. Check carefully whether the data line of the electronic and electronic scales is damaged, and if so, replace it in time.

5. After the power is turned on, the electronic/electronic scale display does not respond.

Solution: Carefully check that the power cable is in good condition and the monitor cable is in good condition. Replace it immediately if it is damaged. If the line connection is no problem, then you can only think of the monitor motherboard or hardware problems, this time only contact the manufacturer to return the factory maintenance.

This article will give you an explanation of the 5 major display failures and solutions for electronic scales. If you want to learn more about electronic scales, please come to our company! Thank you for your great support! Related articles recommended: small electronic scales instrument maintenance knowledge